Choose a side of the house, then select a number to explore a sample finding.
Inspection area 1
Roof covering
AI-generated educational example
Sample inspection comment
The shingles extended excessively beyond the supported rake edge, and several shingles were missing from the adjacent roof slope. Unsupported overhang can leave shingle edges vulnerable to bending and breakage, while missing shingles increase the potential for water entry. The cause and extent of the damage were not determined. Have a qualified roofing contractor verify the edge installation against the shingle manufacturer’s instructions, replace missing or damaged materials, and evaluate the exposed areas for moisture damage.
Inspection area 2
Fogging between panes
AI-generated educational example
Sample inspection comment
Fogging was visible between the panes of the front insulated-glass window, consistent with a failed glazing seal. This reduces visibility and indicates deterioration of the insulated-glass unit. Have a qualified window contractor evaluate and replace the affected glass unit or make other necessary repairs.
Inspection area 3
Water behind the siding
AI-generated educational example
Sample inspection comment
The siding receiving trim at the window and garage-door openings had incomplete joints and water-diversion details. Runoff may be directed behind the siding, increasing the potential for moisture damage to concealed materials. Have a qualified siding contractor evaluate and correct the trim and flashing details in accordance with the manufacturers' installation instructions, and investigate for concealed damage where evidence warrants.
Inspection area 4
Inside the attic
Attic insulation
AI-generated educational example
Sample inspection comment
Insulation: Insulation was thin, displaced, or missing in portions of the vented attic above conditioned rooms. These gaps reduce resistance to heat transfer and can contribute to increased heating and cooling demand and uneven indoor temperatures. Have a qualified insulation contractor evaluate the attic, address accessible air leaks, and correct the insulation coverage without obstructing required ventilation.
Ridge ventilationAI-generated educational example
Sample inspection comment
Ridge ventilation: The opening through the roof sheathing beneath the ridge vent appeared unusually narrow and may restrict attic exhaust ventilation. Have a qualified roofing contractor verify the opening and installation against the vent manufacturer's instructions and correct any deficiencies.
Bathroom exhaust in the atticAI-generated educational example
Sample inspection comment
The bathroom exhaust duct terminated inside the attic instead of outdoors. Moisture staining and surface discoloration were observed on nearby roof framing and sheathing. Moist exhaust air can condense on these surfaces and promote fungal growth and wood deterioration. Have a qualified HVAC contractor route and properly terminate the duct outdoors, and have the affected materials evaluated and repaired as needed.
Inspection area 5
Reading foundation cracks
Vertical foundation crack
AI-generated educational example
Sample inspection comment
Vertical crack: A narrow vertical crack was observed in the foundation wall. Cracking can allow moisture entry and may be associated with shrinkage or movement; its cause and whether it remains active were not determined. Have a qualified foundation contractor evaluate the crack and advise on repair or monitoring. Obtain a structural engineer's evaluation if displacement, continued movement, or other structural concerns are identified.
Horizontal foundation crackAI-generated educational example
Sample inspection comment
Horizontal crack with bowing: Horizontal cracking and inward bowing were observed in the block foundation wall. This pattern may indicate lateral pressure and reduced wall stability. Have a licensed structural engineer promptly evaluate the wall and provide repair recommendations, then have a qualified contractor complete the specified work.
Inspection area 6
Deck connections & stairs
Deck connections
AI-generated educational example
Sample inspection comment
Connections: At the rear deck, several joists lacked hangers at their ledger connections, and the ledger's visible attachment to the house consisted of nails without approved structural screws or bolts. These connections may not adequately support the deck and present a risk of collapse and injury. Have a licensed general contractor evaluate and correct the joist support and ledger attachment. Obtain an engineer's repair design where necessary.
Stair handrailAI-generated educational example
Sample inspection comment
Handrails: The rear deck stairs lacked a graspable handrail. This reduces the ability to maintain a secure handhold and increases the risk of falls. Have a qualified contractor install a securely mounted, graspable handrail.
Inspection area 7
Water heater & furnace
T&P discharge pipe
AI-generated educational example
Sample inspection comment
Missing T&P discharge pipe: The water heater's temperature-and-pressure relief valve lacked discharge piping. If the valve opens, hot water may discharge onto nearby people or materials, creating a scalding and property-damage hazard. Have a licensed plumber install suitable discharge piping with a safe termination in accordance with the water heater manufacturer's instructions and applicable requirements. Do not cap or obstruct the relief-valve outlet.
Thermal expansionAI-generated educational example
Sample inspection comment
Thermal expansion: A pressure-reducing valve was installed on the water supply, and no expansion tank or other thermal-expansion control was visible. If the supply arrangement creates a closed system, heated water can increase system pressure, potentially damaging plumbing and causing relief-valve discharge. Have a licensed plumber determine whether the system is closed and provide properly sized thermal-expansion control as needed.
Furnace combustion airAI-generated educational example
Sample inspection comment
The gas furnace drew combustion air from the enclosed crawlspace, where foundation vents were sealed and no dedicated combustion-air supply was visible. Adequate combustion air could not be verified. An insufficient supply can cause unsafe combustion and carbon monoxide production. Have a licensed HVAC contractor evaluate the equipment, available air volume, and venting, and provide an approved combustion-air arrangement before operating the furnace.
Inspection area 8
Where the water goes
Downspout termination
AI-generated educational example
Sample inspection comment
The right-side downspout discharged directly beside the foundation. Moisture staining and efflorescence were observed on the adjacent crawlspace block wall, with dampness and surface discoloration on nearby floor framing. Concentrated roof runoff can contribute to water entry, and persistent dampness can promote fungal growth and wood deterioration. The full moisture source and extent of damage were not determined. Have a qualified contractor redirect the runoff away from the foundation, evaluate other moisture sources, and repair affected materials as needed.
Crawlspace moisture effectsAI-generated educational example
Inspection area 9
Exterior GFCI protection
AI-generated educational example
Sample inspection comment
The GFCI receptacle on the right exterior wall did not trip when its TEST button was operated. The device may not provide the intended protection against electrical shock. Have a licensed electrician evaluate the receptacle and associated wiring, make necessary repairs, and confirm that the GFCI operates properly. Avoid using the receptacle until corrected.
Educational illustration — four AI-generated house views and sample findings, not an inspection of a particular property. Small architectural details may vary. No client property or inspection measurements are shown.